| Technical details Basic electrical heaters |
![]() |
|
Models |
S 2 | S 3 | S 6 | S 10 | S 17 |
| . | |||||
| power kW | 2 / 1 | 3,5 / 1,75 | 6,3 | 10 | 16,4 / 10 |
| voltage V | 230 | 230 | 400 3 phase | 400 3 phase | 400 3 phase |
| front fuse A | 10 | 16 | 10 | 16 | 25 |
| connecting plug | 230 V 16 A | 230 V 16 A | 400 V 16 A | 400 V 16 A | 400 V 32 A |
| air flow m3 / h | 150 | 570 | 560 | 930 | 1140 |
| temp. rise C | 38 | 17 | 31 | 30 | 40 |
| . | |||||
| thermostat controlled | |||||
| cool down | no | no | yes | yes | yes |
| fan bearing | slide | slide | slide | ball | ball |
| . | |||||
| measurements: | |||||
| length mm | 250 | 350 | 440 | 500 | 667 |
| width mm | 180 | 270 | 270 | 320 | 320 |
| height mm | 300 | 400 | 400 | 530 | 530 |
| weight kg | 5,5 | 10 | 13 | 19 | 25 |
| . | |||||
| heated | |||||
| space m3 (average) | 80 | 140 | 260 | 400 | 680 |
| . |
| . |
| models S 2 - S 17 also include: |
| cool air flow | continuous air flow with no heat on |
| continuous air flow | continuous air flow, thermostat controls the temperature |
| air flow when heating | thermostat controls fan and heating elements both (including cooldown operation) |
| thermostat | Celsius scale controlled thermostat 0 - 40 degrees centigrade |
| - | |
| qualified for | dry and humid surroundings |
| protection degree | IP 54, dust- and splash protected |
| qualifications | FI, EMC, CE |
| . | |
| cover material | powder painted steel casing |
| heating elements | stainless steel covered coils ( coils covered by lamelled metal tubes in model S 2 ) |
| Technical
details heaters for combustible conditions |
![]() |
|
Models |
S 3 PVT | S 5 PVT | S 8 PVT | ||
| . | |||||
| power kW | 3,5 / 1,75 | 5,5 | 8 / 4 | ||
| voltage V | 230 | 400 3 phase | 400 3 phase | ||
| front fuse A | 16 | 10 | 16 | ||
| connecting plug | 230 V 16 A | 400 V 16 A | 400 V 16 A | ||
| air flow m3 / h | 810 | 900 | 820 | ||
| temp. rise C | 12 | 17 | 27 | ||
| . | |||||
| thermostat controlled | |||||
| cool down | no | yes | yes | ||
| fan bearing | slide | ball | ball | ||
| . | |||||
| measurements: | |||||
| length mm | 410 | 500 | 667 | ||
| width mm | 270 | 320 | 320 | ||
| height mm | 380 | 530 | 530 | ||
| weight kg | 9 | 19 | 25 | ||
| . | |||||
| heated | |||||
| space m3 (average) | 140 | 220 | 320 | ||
| . |
| All PVT-models also include: |
| cool air flow | continuous air flow with no heat on |
| continuous air flow | continuous air flow, thermostat controls the temperature |
| air flow when heating | thermostat controls fan and heating elements both (including cooldown operation) |
| thermostat | Celsius scale controlled thermostat 0 - 40 degrees centigrade |
| - | |
| qualified for | dry and humid surroundings and combustible conditions |
| protection degree | IP 54, dust- and splash protected |
| qualifications | FI, EMC, CE |
| . | |
| cover material | stainless steel |
| heating elements | stainless steel covered coils |
.
.
| Wall racks | ST 10 | ST 20 |
| for models | S 3, S 6, S 10 , S 3 PVT and S 5 PVT | S 17 and S 8 PVT |
| SIURA OY |
|